Evaluation of image quality and lesion perception by human readers on 3D CT colonography: comparison of standard and low radiation dose

Fisichella, Valeria A, 1974 (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
Båth, Magnus, 1974 (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
Johnsson, Åse (Allansdotter), 1966 (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
show more...
Jaderling, F. (author)
Bergsten, T. (author)
Persson, U. (author)
Mellingen, K. (author)
Hellström, Mikael, 1950 (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
show less...
 (creator_code:org_t)
2010
2010
English.
In: European Radiology. - 1432-1084. ; 20:3, s. 630-9
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • AIMS: We compared the prevalence of noise-related artefacts and lesion perception on three-dimensional (3D) CT colonography (CTC) at standard and low radiation doses. METHODS: Forty-eight patients underwent CTC (64 x 0.625 mm collimation; tube rotation time 0.5 s; automatic tube current modulation: standard dose 40-160 mA, low dose 10-50 mA). Low- and standard-dose acquisitions were performed in the supine position, one after the other. The presence of artefacts (cobblestone and snow artefacts, irregularly delineated folds) and the presence of polyps were evaluated by five radiologists on 3D images at standard dose, the original low dose and a modified low dose, i.e. after manipulation of opacity on 3D. RESULTS: The mean effective dose was 3.9 +/- 1.3 mSv at standard dose and 1.03 +/- 0.4 mSv at low dose. The number of images showing cobblestone artefacts and irregularly delineated folds at original and modified low doses was significantly higher than at standard dose (P < 0.0001). Most of the artefacts on modified low-dose images were mild. No significant difference in sensitivity between the dose levels was found for polyps >/=6 mm. CONCLUSIONS: Reduction of the effective dose to 1 mSv significantly affects image quality on 3D CTC, but the perception of >/=6 mm lesions is not significantly impaired.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

Radiology
Colon
CT colonography
Polyp
Radiation

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view